What are the characteristics of induction of urinang bucket bkets, how should ibstalled? 2024-07-22 06:57:43 internet

Induction of urine bucket fluxers must be used daily. It can be seen in the toilet in the public toilet. What is the structure of the induction of the urine bucket, and how to install the urine flush machine?I believe everyone wants to understand, so I will explain the structural characteristics of induction of induction.
How to repair the urine bucket sensor
1. Long flowing water, cant stop the water
1. Eliminate the power supply failure, if the power is disconnected at the moment when the solenoid valve is turned on (the battery power is insufficient or the transformer is bad), the sensor of some brands will cause the solenoid valveEssence
2. Clean up the solenoid valve
Determine whether the solenoid valve is faulty. After the urine bucket sensor is used for a long time, there may be a membrane that blocks the solenoid valve to block the film, so that the film cannot be switched normally.The screws on the valve head are unscrewed (usually 4 screws), remove the valve head, remove the film, please pay attention to the operation order and installation method. Do not lose the magnetic stick and film spring on the valve head (note, note thatSome solenoid valves do not have a spring, and the main function of the spring is to prevent the film from blocked the film). Whether there is impurities under the membrane. If so, you can rinse it with water and then install it in the original order.If the same fault is still the same, the solenoid valve may be broken, and the solenoid valve needs to be replaced.
3. Sensor distance
If the inductive distance is too long, the solenoid valve will always be in a working state and keep flowing water. If there is a distance to adjust the resistor after the induction circuit, please adjust the short distance and then see if the water can be stopped. If there is no adjustable resistor, the power supply is disconnected.Wait for a few seconds, then re -insert the power, and use your hand to respond to the induction window, and gradually pull the distance until you think the normal distance, stop, your hands are still facing the induction window, waiting for the induction window to confirm and fix the induction distance.If the problem cannot be solved after adjustment, it may be that the induction circuit is broken.
Second, do not feel, do not produce water
When confirming that the equipment water valve is not closed, most brands can follow the following steps to eliminate the fault:
1. Eliminate the battery or transformer failure, power if the battery is used.Whether the induction indicator lights flickered quickly. If it is, the battery is out of power, and change the new battery as soon as possible.
If the indicator light is not on, please change the new battery. After replacing, if the indicator on the sensor does not respond, it may be that the sensor is broken.
2. If the power supply is power supply, check whether the transformer works normally (using a multimeter or other inductive panels to judge, operate 220V, the power must be operated by professional staff, pay attention to safety).If the light does not respond, it may be that the sensor is broken.
3. Eliminate sensors and electromagnetic valve faults
If the power supply is normal, the other sensors of the same model are moved to the faulty device, and the power supply and solenoid valve are connected. If the flushing work is normal, it means that the induction is broken; otherwise the solenoid valve may be broken.
Third, small water output
1. Exclude the impact of water supply and water pressure
See if other devices have the same problem. If this is the case, first determine whether the water pressure is smaller than the original. If it is, the water pressure of water supply is reduced.
2. Clean the filter
Turn off the water valve and clean up the water intake filter of the urnal bucket solenoid valve; some urinating sensors come with a filter, you need to use a word (or inner hexagonal, etc.) to remove the cleaning. Some are only on the battery valveThe front end of the water is added with a filtering steel wire mesh. You need to remove the solenoid valve and clean the front -end steel wire filter.
How to install the urine bucket sensor
The inductive switch can be divided into 86 induction switches and top -suction switchs from the shape.The 86 -type induction switch is consistent with the size of the traditional mechanical wall switch, which can directly replace the original wall switch.Because the left and right sides on the left and right sides are larger than the upper and lower sides, the front axis should be perpendicular to the direction of the walking channel when installing the switch, so as to achieve the best induction effect.
After installing the switch, power is added. When the environmental light is sufficient, the light bulb will flash three times. The initialization of the light after one minute is over. The switch enters the monitoring state.Continuous work; after the person leaves, the switch is automatically delayed and closed.
After the switch is installed, power is added. When the environmental light is insufficient, the switch directly enters the monitoring state. If people do not leave and the activity, the switch will continue to work.If you are not satisfied with the delay time or light, you can adjust it through the Timer and Dimmer of the 86 wall switch.During the adjustment, use a filament knife to twist lightly. Do not force it too hard.For top -suction sensing switch, open the surface cover to see the adjustment potentiometer.
Structural characteristics of urinating bucket induction flusher
1. Adopt intelligent selection of a single and double segment water flushing method. The sensor can intelligently perform intelligent water flushing control according to the frequency of the urine fighting to avoid wasting the waste of water resources.
2. It can be set up automatically once when no one is used for 24 hours to prevent the water in the water storage bend from dried up, causing the odor to return.
3. In -bucket rinse is completed through sensors, without artificial operation, thoroughly washed, leaving no odor, ensuring indoor air cleaning, and preventing bacterial transmission.
4. You can adjust the sensitivity (range) according to different environmental environment.
5. Made of stainless steel materials, smooth lines, beautiful and generous, durable.
6. Digital technology, ultra -low energy consumption (DC products use 4 5 alkaline batteries, static current ≤ 60 μA).
7. Built -in filter (non -professional personnel can easily clean the filter).
8. There is a battery replacement prompt function. When the battery electricity is insufficient, the indicator light is often on, and it is prompted to replace the battery.