HOME > NEWS > Appliancesarticle

What are the advantages of inverterir conditions? 2024-07-21 04:47:36 internet

The inverter air conditioner refers to the conventional air conditioner of the inverter.The compressor is the heart of the air conditioner, and its speed directly affects the use efficiency of the air conditioner. The inverter is the control system used to control and adjust the speed of the compressor to make it always in the best speed state, thereby improving the energy efficiency ratio.
What are the advantages of inverter air conditioners
Energy -saving: Because the inverter air conditioner is installed through the interior inverter, the heart of the air conditioner is adjusted at any time -the operating speed of the compressor can be used to achieve reasonable use of energy; since its compressor will not be opened frequently, the compressor will maintain a stable working state.This allows the air conditioner to achieve an effect of more than 30%of energy saving as a whole.At the same time, this has a very obvious effect on the reduction of noise and extending the service life of the air conditioner.
Low noise: Due to the balanced operation of the frequency frequency air conditioner, the vibration decreases, and the noise decreases.
High temperature control accuracy: It can control the cooling (thermal) amount of air -conditioning machine by changing the speed of the compressor.The amount of refrigeration (thermal) has a variable range. For example, the refrigeration volume of 36GW frequency conversion changes to 360-4000W, and the heating volume changes to 300-6800W. Therefore, the indoor temperature control can be accurate to ± 1 ° C, which makes the human body feel comfortable.
Fast temperature adjustment speed: When the temperature adjustment temperature of the room is large, the inverter air conditioner is turned on, that is, work at the maximum power, so that the room temperature rises or decreases to the adjustment temperature, and the effect of refrigeration (thermal) is obvious.
Low voltage requirements: The inverter air conditioner is more adaptable to the voltage, and some inverter air conditioners can even be activated at 150-240V voltage.
Low environmental temperature requirements: The inverter air conditioner is very adaptable to the ambient temperature, and some products can even be started at the environmental temperature of -15T.
One -to -two intelligent temperature control: It can intelligently identify the size of the room and allocate the cold (thermal) amount, so that the rooms of different sizes are the same temperature.
Keep the room temperature constant: The inverter air conditioner uses the frequency conversion compressor, and the frequency frequency air conditioner can automatically adjust the operating frequency of the compressor according to the change of the cold (thermal) load in the room.After setting the temperature, the inverter air conditioner runs at a lower frequency to avoid the discomfort caused by the severe changes in room temperature.When the frequency of the load hours is low, the power consumption of the compressor is small, and at the same time avoid frequent start and stop, thereby saving more power.
How to buy inverter air conditioners
Since the inverter air conditioner is a high -tech product composed of a computer -controlled inverter and the frequency conversion compressor, users should pay attention to the following points when purchasing, installation and use
① When buying, determine the size of the selected inverter air conditioner according to the room area (generally a room for a frequency conversion air conditioner can be used in a room of about 14 square meters), and try to avoid use in the case of ultra -area.
② During the installation and maintenance process, when a refrigerant is needed, the air conditioner should be set to run in a trial method or by adjusting the setting temperature to work in the state of 50Hz, and then add refrigeration according to the amount according to the amount.Prevention.
③ The outdoor unit of the inverter air conditioner has a microcomputer -controlled inverter. The printing circuit board is more easily damaged in a high temperature and humid environment. Therefore, its outdoor unit should be installed in a dry and ventilated place to avoid sunlight exposure and rain.If the outdoor unit is automatically stopped after booting, it should be immediately stopped for repair to prevent the failure from expanding.
④ Do not set the temperature too low in daily use to avoid air -conditioners from running at a high speed for a long time.It is best to set in the automatic running method so that it can be refrigerated quickly and saving power.
⑤ When buying, see if the technology is mature.A number of Chinese air -conditioning companies have launched their own inverter series, and they have also taken many beautiful and beautiful names. However, under the financial crisis, consumers are becoming more and more rational, simply use a "frequency conversion" label to attract consumers.It has passed, and you need to come up with the "real skills" -the core technology of mature.
⑥ When buying, see if the quality is stable. Quality is the lifeline of the product, and high -quality products can be based on the market for a long time to accept consumers.For the "new pet" inverter air conditioner, its quality stability has a great relationship with the maturity of technology.However, the quality of the product is over, and a third party is required to verify.
Look at whether the service is professional.For the complex frequency frequency air conditioners, the low -level "booing and warmth" cannot meet the needs of consumers. Professional services will become another indicator for consumers to choose air conditioners.
Inverter air conditioner should pay attention to what needs to be paid attention to
① Air conditioning outdoor unit -must choose a well -ventilated position to install, otherwise it will cause air conditioners to work at low frequency, and the compressor and frequency conversion module will be easily protected frequently, which will cause the shutdown (the current is too large).
② The connection line must be installed with a solid wire clip to avoid pulling off and breaking the connection. The joints must be firm and reliable, otherwise it is easy to cause fire and cause fire and other accidents: Poor signal line contact will cause it to cause it to be unable to take off or the compressor frequently.Start and stop.
③ All inverter air conditioners must be grounded reliable. If the user does not have ground lines, it is necessary to find a way to solve it. When the air conditioner does not have ground lines, the phenomenon of obstacles is often opened and stopped, and the work is unstable.
④ In the installation of all inverter air -conditioning machines, the internal and external machines are connected, and the special wiring of the frequency converter must be used.

Related tags: Appliances