The wall -mounted boiler is actually the abbreviation of the gas wall hanging boiler.The term "wall -mounted boiler" term foreign language, the full name is: "gas wall -mounted heating furnace", the standard of our country is: "gas wall -mounted fast heating water heater", but it is not a traditional gas water heater, and the water heater, and the water heaterThere is a essential difference.It has a variety of safety protection measures such as anti -freezing protection, anti -dried burning protection, unexpected fire protection protection, high temperature protection, pumping card prevention protection.It can be connected to the indoor temperature controller to achieve personalized temperature regulation and energy saving.
Wall -mounted stove water pressure
Experiments show that as long as the water pressure in the wall-mounted boiler is kept between 0.5-1.5Pa, it will not affect the normal use of the wall-mounted boiler at all.If the water pressure is lower than 0.5Pa, it may cause the hot water to be cold and hot or not started normally. If the water pressure is higher than 1.5Pa, the system pressure increases when heating.Water may cause unnecessary losses. Normally, you can make up for water for about one to two months.
Wall -mounted boiler repair
1. Insufficient stress failure phenomenon: The pump does not turn to operation, the controller is alarm, and the fault code displayed by the display screen is insufficient pressure.Causes of faults: A) Pipelines are short of water, and the pressure gauge displays insufficient water pressure.b) Pressure switch failure.c) There are a lot of air in the pipeline system.Solution: A) Pipelines are hydrated; if the pipeline leaks, find a way to block it.b) Use a multimeter to detect. If the pressure switch is not connected, replace the pressure switch; if the contact is poor, it will be re -connected; if the line is disconnected, the wire is replaced;c) exhaust the pipeline system.
Top ten brands of wall -mounted boilers
How to use wall -mounted boilers
Second, how to use the most gas -saving wall -hung boiler (1) Solar terms 1. Close or lower the heating film valve of uninhabited rooms: If your housing area is large, the room is more, and the population is relatively small, then thenThe radiator valve in a room with a low frequency can be closed or tuned at all. This is equivalent to reducing the heating area, not only energy saving, but also the increase in the heating temperature of the normal use of the normal use will also increase, reducing gas consumption.
Wall -mounted furnace principle
The gas wall -mounted boiler mainly ignites after mixing the gas and the air premature, and heats the heat of life through the heat exchange system, and then heated the air through the heat dissipation at the end to heal or heating.The working process of the gas wall -mounted boiler is: When the boiler is standby, when the boiler perceives the heating demand, the fan starts, and starts for 30 seconds "front blow" to form a burning warehouse.Start, turn on the gas solenoid valve, the gas enters the combustion warehouse and the air premix; the circulating water pump begins to work; at the same time, the thermal electrode is discharged to form an arc to ignite the gas.The circulating water pump sent hot water out of the secondary system thermal exchange for heating or heating.